Waterproof X®1 is state of the art, multi-injectable injection hose system, used
to seal joints in concrete against water egress. Waterproof X®1 injection hose is used to transport grouting materials and then disperse them into the concrete joint via micro openings along the hose.
Waterproof X®1 injection hose is a highly resistant, robust, fully tested, single channel injection hose system that is made of specially developed PVC materials.
Waterproof X®1 has the ability for multi-injectable grouting processes. This ability allows the system to be re-injectable for the lifetime of the structure, giving total peace of mind and assurance that the structure can be fully sealed and resealed. This is a great advantage if movement or shrinkage occurs between the concrete joint faces of the structure.
Note: The product’s design and performance, its intended use, installation and final confirmation and approval for use must be provided by the project’s Design Engineer and Project Manager.
Unsealed construction joints can decisively lessen the durability and utility-value of concrete structures. Nowadays, injection hose systems are being increasingly used for sealing construction joints in waterproof concrete structures. Their advantages are numerous when compared to traditional waterstop systems. It is not always required to inject the hose but usually only if the joint is leaking, thus making it a very cost effective procedure.
The area of application is usually at the construction joint (other application areas can be applied) where hardened and fresh concrete have to be joined in such a manner that the sealing effect of the construction joint is fulfilled equally.
Simple and rapid installation is achieved at all positions, levels and angles. Waterproof X®1 can also be laid where the installation of traditional systems is constructively impossible; for example, on geometrical complicated surfaces such as sheet piling, diaphragm and contiguous pile walls and old to new construction.
Reliable sealing of construction joints, cracks in construction joints, and destroyed areas of concrete (gravel pockets and cavities) can be filled via Waterproof X®1. Previously this has not been possible to achieve with conventional waterstop systems.
Waterproof X®1 is used in all types of construction joints and in particular during the construction of water and sewage treatment plants, dams, barrages, underground garages, tunnels and the construction of foundations, basements, bridges and power stations.
Toggle Content
Waterproof X®1 injection hose is equipped with micro openings (injection ports), equally spaced over its entire circumference, which provides Waterproof X®1 injection hose with optimum grouting characteristics. During the injection process, the microscopic ports open at 1 Bar and injected material is then allowed to perform its task of penetrating the construction joint that requires grouting. As a result, a more secure and longer lasting sealing of the construction joint is achieved.
The micro openings prevent any infiltration of concrete silt and foreign bodies into the injection hose itself. After successful injection, the pressure is released, which causes the micro openings to close. The injection channel can then be flushed out with water, without the threat of any injection material seeping back into the injection hose or water injecting into the joint during the flushing process. The specially designed micro openings are designed in such a way that they act as valves, allowing the release of material out of the hose but not back into it.
Note: Only acrylic gel or ultra-fine cement can be used for re-injectable processes.
Note: Please refer to the manufacturer’s installation procedures and guidelines (available upon request).
Note: Installation and injection method processes are available upon request. Fully trained specialist contractors are available to perform the installation and injection processes for Waterproof X®1.
This warranty only applies when any injection grout, resin OR any other materials recommended by CJSA is used in injecting through the Waterproof X®1 hose system. Should any UNAUTHORIZED product be used in injecting the Waterproof X®1 hose this will void any perceived OR written warranty that may relate to the Waterproof X®1 products.
Where shown on the drawings, the injection hose system shall be Waterproof X®1, multi-injectable, single channel, PVC injection hose with micro opening injection ports as supplied by CJSA. The injection hose system must have the ability to be a multi-injectable for the life time of the structure and proof of this is to be provided by an independent laboratory test report and be submitted to and accepted by the engineer. All components of the system must be original parts supplied from the manufacturer.
The information and the recommendations relating to the application and end use of this product are given in good faith and are based on the information provided by the manufacturer of the product and/or the Company’s current knowledge and experience in connection with the product when properly stored, handled and applied under normal conditions and no liability of final function at the job site is assumed. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability of, or fitness for, particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written and/or oral recommendations, or from any other advice offered by the Company.
The Company also has no express or implied knowledge of any particular purpose for which the product is required and any such information given will not be taken into account in the supply of this product. No responsibility or liability by the Company will be accepted for misuse, misreading or derivation from recommended guidelines in respect of this product and the user shall determine the suitability of the product for his intended use and assume all risks and liability in connection
therewith. The information contained in our brochure may change at any time without notice. Any use of this product, Waterproof X®1, in any application should be approved as suitable for use/application by the Design Engineer and Project Manager.